Series Vita Confortfresh Air Cooled Air Handling

Overview:

As Comfort Air-conditioning, It Can Be Widely Used In Hotels, Theaters, Shopping Malls, Office Buildings, Schools And Other Places; As For Industrial Use Air Conditioning, It Can Also Meet The Electronics, Chemical, Medical, Pharmaceutical, Cigarettes, Food, Light Industry And Other Industries Needs.

Easy Maintenance
direct Expansion 
Galvanized Steel Cabinet
Insulated Cabinet
Easy To Install
Available Capacities 090Kbtu To 480Kbtu

Download:

Data Sheep - Manejadora HM
Ficha técnica - Manejadora Serie HME
Copper-aluminum coil
Quiet Equipment
Real warranty
Excellent cost-benefit
Excellent performance
Easy Instalation /Maintenance
Isolated cabinet

Vita Series Air Cooled Air Handling-HME090X4

Overview:

Capacity (Cooling, TR) 7.5 TR
Capacity (Cooling, Btu/hr) 90000 Btu/h
SEER 13 ---
Voltage / Phase / Frequency (V/Φ/Hz) 220-460/3/60 V/PH/HZ
Amp Rating (Amp) (indoor) 6.5 Amp
Indoor Air Flow (indoor) 3000 CFM
Refrigerant Type R410a ---
Filters (size) 16X24X2 pulg
Filters (quantity) 4 ---
Liquid Line 1/2 pulg
Suction Line 1-1/8 pulg
Number of Circuits 2 ---
Blower Motor (Power). 1.5 Hp
Blower Motor (Speed) 761 rpm
Coil (Area ft²) 8.3 ft²
Coil (number of rows) 3 ---
Net Dimension (W/D/H, Indoor) 49-1/16/28-3/8/56-3/16 pulg
Blower (diameter x length x Bushing) 15x15x1 pulg

Component:

Vita Series Air Cooled Air Handling-HME120X4

Overview:

Capacity (Cooling, TR) 10 TR
Capacity (Cooling, Btu/hr) 120000 Btu/h
SEER 13 ---
Voltage / Phase / Frequency (V/Φ/Hz) 220-440/3/60 V/PH/HZ
Amp Rating (Amp) (indoor) 8.5 Amp
Indoor Air Flow (indoor) 4000 CFM
Refrigerant Type R410a ---
Filters (size) 16X24X2 pulg
Filters (quantity) 4 ---
Liquid Line 5/8 pulg
Suction Line 7/8 pulg
Number of Circuits 2 ---
Blower Motor (Power). 2 Hp
Blower Motor (Speed) 800 rpm
Coil (Area ft²) 10.01 ft²
Coil (number of rows) 3 ---
Blower (diameter x length x Bushing) 15x15x7/8 pulg
Filters (type) LAVABLES , GUATA 1/4 ---

Component:

Vita Series Air Cooled Air Handling-HME150X4

Overview:

Capacity (Cooling, TR) 12.5 TR
Capacity (Cooling, Btu/hr) 150000 Btu/h
SEER 13 ---
Voltage / Phase / Frequency (V/Φ/Hz) 220-440/3/60 V/PH/HZ
Indoor Air Flow (indoor) 3003/5000/5505 CFM
Liquid Line 1/2 pulg
Suction Line 1-1/8 pulg
Blower Motor (Speed) 850 rpm
Number of Circuits 2 ---
Blower Motor (Power). 2.5 Hp
Coil (number of rows) 4 ---
Coil (Area ft²) 10.01 ft²

Component:

Vita Series Air Cooled Air Handling-HME180X4

Overview:

Capacity (Cooling, TR) 15 TR
Capacity (Cooling, Btu/hr) 180000 Btu/h
SEER 13 ---
Voltage / Phase / Frequency (V/Φ/Hz) 220-440/3/60 V/PH/HZ
Amp Rating (Amp) (indoor) 13 Amp
Indoor Air Flow (indoor) 570/6000/9295 CFM
Refrigerant Type R410a ---
Filters (size) 16X24X1 pulg
Filters (quantity) 6 ---
Suction Line 1-1/8 pulg
Liquid Line 1/2 pulg
Blower Motor (Speed) 1800 rpm
Number of Circuits 2 ---
Blower Motor (Power). 3 Hp
Coil (Area ft²) 16.9 ft²
Coil (number of rows) 3 ---
Blower Motor (quantity) 2 ---
Net Dimension (W/D/H, Indoor) 78/28-1/4/55 pulg
Blower (diameter x length x Bushing) 15X15X1-3/16 pulg
Filters (type) LAVABLES , GUATA 1/4 ---

Component:

Vita Series Air Cooled Air Handling-HME240X4

Overview:

Capacity (Cooling, TR) 20 TR
SEER 13 ---
Voltage / Phase / Frequency (V/Φ/Hz) 220-440/3/60 V/PH/HZ
Indoor Air Flow (indoor) 8000 CFM
Filters (size) 16X24X1 pulg
Filters (quantity) 6 ---
Liquid Line 5/8 pulg
Suction Line 1-1/8 pulg
Number of Circuits 2 ---
Blower Motor (Power). 5 Hp
Coil (number of rows) 4 ---
Coil (Area ft²) 19.6 ft²
Blower Motor (quantity) 2 ---
Net Dimension (W/D/H, Indoor) 78-1/16/27-7/16/55-3/16 pulg
Blower (diameter x length x Bushing) 15X15X1-3/16 pulg
Filters (type) LAVABLES , GUATA 1/4 ---

Component:

Vita Series Air Cooled Air Handling-HME300X4

Overview:

Capacity (Cooling, TR) 25 ---
SEER 13 ---
Voltage / Phase / Frequency (V/Φ/Hz) 220-440/3/60 V/PH/HZ
Indoor Air Flow (indoor) 10000 CFM
Refrigerant Type R410a ---
Filters (size) 16X20X1 /16X24X1 pulg
Filters (quantity) 8 ---
Suction Line 1-3/8 pulg
Liquid Line 5/8 pulg
Number of Circuits 2 ---
Blower Motor (Power). 5 Hp
Coil (number of rows) 2 ---
Coil (Area ft²) 19.8 ft²
Blower (diameter x length x Bushing) 15X15X1-3/16 pulg
Net Dimension (W/D/H, Indoor) 89/27-7/16/56 pulg
Filters (type) LAVABLES , GUATA 1/4 ---

Component:

Vita Series Air Cooled Air Handling-HME360X4

Overview:

Capacity (Cooling, TR) 30 TR
Capacity (Cooling, Btu/hr) 360000 Btu/h
SEER 13 ---
Voltage / Phase / Frequency (V/Φ/Hz) 220-440/3/60 V/PH/HZ
Indoor Air Flow (indoor) 12000 CFM
Refrigerant Type R410A ---
Filters (size) 20 X 24 X 1 pulg
Filters (quantity) 8 ---
Depth dimension 31 3/4 pulg
Dimension High 65 9/16 pulg
Dimension Width 100 17/32 pulg
Suction Line 5/8 pulg
Liquid Line 1 3/8 pulg
Fan Motor (FLA) 23.2@220V/11.6@440V Amp
Fan Motor (Power). 7.5 Hp
Fan Motor (Speed) 1800 rpm
Number of Circuits 2 ---
Coil (Area ft²) 24.86 ft²
Coil (number of rows) 4 ---
Blower (diameter x length x Bushing) 18x18x1-3/16 pulg

Component:

Vita Series Air Cooled Air Handling-HME480X4

Overview:

Capacity (Cooling, TR) 40 TR
SEER 13 ---
Voltage / Phase / Frequency (V/Φ/Hz) 220-440/3/60 V/PH/HZ
Indoor Air Flow (indoor) 16000 CFM
Refrigerant Type R410a ---
Filters (size) 20X24X1 pulg
Filters (quantity) 8 ---
Coil (number of rows) 4 ---
Coil (Area ft²) 29.54 ft²
Blower Motor (quantity) 2 ---
Net Dimension (W/D/H, Indoor) 100-17/31-5/8/67-29/32 pulg
Filters (type) LAVABLES , GUATA 1/4 ---

Component: